How to read a peptide COA, line by line

Reviewed 16 sourcesPublished by PepVault

How to read a peptide certificate of analysis: the lot number, HPLC purity, mass spec identity, peptide content, endotoxin, and what a COA can't tell you.

A man in a light-blue shirt reading a sheet of paper at a table, a crimp-sealed glass vial and coffee beans beside him
Last reviewed
Sources
16
Questions
9
Compounds
2

The short answer

Read a peptide COA in four checks. First, its lot number must match your vial's. Second, identity: the mass found by mass spectrometry should match the expected mass, 1,419.5 daltons for BPC-157. Third, HPLC purity such as 99% measures the peptide signal, not how much of the powder is peptide, so look for peptide content too. Fourth, endotoxin, sterility, solvents and metals, each with a limit.

Every number checked at its primary source · · 16 sources · How we research

Evidence: Pharmacopeial and regulatory standards (FDA guidance citing USP <71> and <85>, ICH Q3C and Q3D, 21 CFR 211), PubChem, and two peer-reviewed lab tests of peptide products bought online; one peptide-content study's results in animals are mouse data.

A man in a light-blue shirt reading a sheet of paper at a table, a crimp-sealed glass vial and coffee beans beside him

What do you need to read a COA?

A certificate of analysis (COA) is a lab's report on one batch, also called a lot: what was tested, by which method, the limit each result had to meet, and the result. To read one, you need four things at hand:

What you need

  • The COA itself, as a PDF or on paper, with the lab's name, the test date and the lot number.
  • Your vial's label, for its lot number and the amount it says it holds, such as 10 mg.
  • Your peptide's expected mass, in daltons (Da), the unit chemists use for the weight of one molecule. PubChem, the US National Library of Medicine's chemistry database, lists it: 1,419.5 Da for BPC-1575.
  • A note of which tests the COA has, because a test that is missing is an unknown, not a pass.
A smiling woman in a blue top leaning on her kitchen counter with her phone and a notebook

PepVault for iPhone

Keep your protocol in PepVault

PepVault's vial record has a batch note: type the COA's lot number there when you add the vial, and the lot stays with that vial's record.

Download on the App Store

7 days free on the yearly plan for new subscribers.

How do you check a COA, step by step?

  1. Find the lot number on your vial's label and on the COA. If the two differ, the COA describes some other batch and tells you nothing about your vial.
  2. Check that the COA names the same peptide and the same amount per vial as the label.
  3. Compare the identity result with the expected mass. A reading near half or a quarter of it can be the same molecule carrying two or four charges, so check which form the COA says it reports.
  4. Read the purity line: the method (usually HPLC), the limit, such as ≥98%, and the result. A result with no limit beside it has nothing to meet.
  5. Look for a peptide content line, sometimes called net peptide content: the share of the powder's weight that is the peptide. Without it, you don't know how much peptide the vial holds.
  6. Check the endotoxin line for a number, its unit, EU/mg (endotoxin units per milligram), and its limit.
  7. Check the lines for sterility, residual solvents and elemental impurities (heavy metals), and mark each one the COA leaves out.
  8. Note the lab's name, who signed or approved the report, the test date and the date the report was issued.
  9. Keep the COA filed under the vial's lot number.

PepVault's vial record has a batch note: type the COA's lot number there when you add the vial, and the lot stays with that vial's record. Track your vials in PepVault

What does a peptide COA look like?

Below is a constructed example for a 10 mg vial of BPC-157, written for this guide. It is not any company's COA. Every number in it is invented for teaching except the expected mass5 and the acetonitrile limit3.

TestMethodSpecificationResult
AppearanceVisualWhite powderConforms
IdentityMass spectrometry1,419.5 ± 1.0 Da1,419.6 Da
PurityHPLC, UV detector≥ 98.0%99.1%
Peptide contentAssay against a reference standardReport result82%
Counter-ionIon chromatographyReport resultAcetate, 11%
EndotoxinLAL test, USP <85>≤ 1 EU/mg< 0.1 EU/mg
SterilityUSP <71>No growthNo growth
Residual solventsICH Q3CAcetonitrile ≤ 410 ppm60 ppm
Elemental impuritiesICH Q3DWithin ICH limitsConforms
A certificate of analysis beside a vial, the lot field circled on both and joined by a line
The first check: the lot on the COA and the lot on the vial are the same.

Read each row across: the method is named, the specification is stated, and the result sits inside it. “Conforms” is a pass with no number behind it, so a COA that prints the number tells you more.

What does HPLC purity actually measure?

HPLC (high-performance liquid chromatography) pushes a dissolved sample through a packed column. Different molecules come out at different times, and a detector draws each one as a peak. The purity figure is the main peak's area as a share of the total area of all the peaks the detector recorded, so 99.1% means the other peaks add up to 0.9%.

An HPLC trace with one tall peak holding 99.1% of the area and two small peaks, a chain missing one amino acid and an oxidised chain
Purity is the tall peak's share of all the peaks: here 99.1%.

Those other peaks are mostly near-copies of the peptide made during synthesis: chains missing an amino acid or carrying an extra one, amino acids flipped into their mirror form, oxidized chains and leftover protecting groups, plus breakdown products that form later10.

Purity can't do two things. It doesn't prove the main peak is the right peptide, which is the identity line's job. And it only counts what the detector sees: in one study, the powder in three vials gave a single peptide signal and was still mostly something else by weight6.

How does mass spectrometry confirm the peptide's identity?

Mass spectrometry weighs molecules. The lab compares the mass it observes with the mass the peptide's sequence predicts, and a match within the stated tolerance says the molecule is the right size to be that peptide.

The expected mass comes from the amino acids. BPC-157 is a chain of 15 of them, GEPPPGKPADDAGLV. Adding up the average masses of the 15 amino acids as they sit in the chain, plus one water molecule for the chain's two ends, gives 1,419.5 Da, the molecular weight PubChem lists. PubChem also gives the monoisotopic mass, 1,418.7 Da, the mass when every atom is its most common isotope5. A COA may print either one, and should say which.

Peptide SkySee BPC-157 as a molecule53 peptides as a night sky in 3D. Each star opens into its molecule, one bead per amino acid, with the measured shape where one exists.Open the Peptide Sky

The instrument usually sees the molecule with extra protons attached, so it reads a mass-to-charge ratio. BPC-157 carrying two protons shows up near 710.4, worked out from PubChem's monoisotopic mass5. Semaglutide, about 4,114 Da15, was identified in one study by its signal at 1029.3, the molecule carrying four protons6.

Why is peptide content different from purity?

Purity says what share of the peptide signal is the right peptide. Peptide content says how much of the powder's weight is peptide at all, and the two can sit far apart. Solid-phase synthesis, the usual way peptides are made10, uses trifluoroacetic acid (TFA), so the peptide comes out as a salt with a counter-ion, a charged partner molecule, attached9. TFA can be swapped for chloride or acetate916. For the peptides one lab studied, TFA was expected to make up about 25% of the salt's weight and measured up to 35%9.

A 2014 study of one research peptide found two batches of similar purity holding 45% and 72% peptide by weight, and noted that for that peptide this share runs from under 50% to over 90%, the rest mainly counter-ion. Injected into mice to set off a model of nerve inflammation, the two batches gave different disease scores8.

One bar for a vial’s powder by weight: peptide 82%, acetate counter-ion 11% and the other 7%
99% pure is about the peptide signal; this bar is about the powder's weight.

So a 10 mg vial at 99% purity can hold well under 10 mg of peptide. The COA should say whether the label's 10 mg means the powder or the peptide in it.

What do the endotoxin, sterility, solvent and metal lines mean?

Endotoxin is a molecule from the cell walls of Gram-negative bacteria, left behind even when no bacteria are alive6. In an injection it acts as a pyrogen, a substance that causes fever14. Labs measure it with the LAL (Limulus amebocyte lysate) test, which the FDA has accepted in place of the rabbit pyrogen test for more than 30 years1. The limit is calculated from the dose by the method in USP <85>, so it differs from product to product, and each result should come with its own1.

Sterility (USP <71>) checks samples for live microbes in growth media2. It catches less than it seems: the FDA notes that a 10,000-unit lot with 0.1% of its units contaminated, tested with 20 units, has a 98% chance of passing2. Sterile is also not endotoxin-free: three online semaglutide vials held no live microbes when tested, yet the lab reported endotoxin in all three6.

Residual solvents are what's left of the liquids used in making the product. ICH Q3C, the international standard, sorts them into three classes: class 1 to be avoided, class 2 to be limited, such as acetonitrile at 410 ppm (parts per million), and class 3, lower risk, such as acetic acid, acceptable up to 5,000 ppm without justification3.

Elemental impurities, often printed as heavy metals, follow ICH Q3D. For the four it puts in class 1 as human toxicants, arsenic, cadmium, mercury and lead, the permitted daily exposures for injected products are 15, 2, 3 and 5 micrograms a day4.

When to get help If you get a fever, chills or redness spreading from an injection site, see a doctor, and bring the vial and its COA.

What did labs find when they tested peptides bought online?

In a 2024 study, researchers in Hungary bought semaglutide from illegal online pharmacies and tested the three vials that arrived. The labels or sellers' documents claimed at least 99% purity. The lab found semaglutide, no peptide-like impurities, and more of it than the label said, 29% to 39% over. But semaglutide made up only 7.7% to 14.4% of the powder's weight, and the lab reported endotoxin in every vial, one at 9.0 EU/mg6.

A Belgian study tested the ten falsified peptide drugs most often found on its market, bought from three suspected illegal internet pharmacies. Purity ran from 5% to 75% for the peptides containing cysteine. One sample held lead, and several held arsenic, all of it the more toxic inorganic form, at concentrations up to ten times the ICH limit for injected drugs7.

Commonly reported: people describe a COA whose lot number doesn't match the one on their vial, or the same COA shown for many different lots. These are user reports, not studies.

What can't a COA tell you?

  • That it's your vial. A COA describes one lot, tested once. Only a matching lot number links it to the vial in your hand, and that link is the label's word.
  • That the numbers are right. Even drug makers under FDA rules may accept a supplier's report of analysis only if they run at least one specific identity test themselves and validate the supplier's results at regular intervals11.
  • How it holds up. A COA is a snapshot on its test date. How long a product keeps, and how to store it, comes from a separate stability testing program12; no COA shows how a vial fared in shipping or after mixing.
  • What wasn't tested. A missing line is an unknown, and a sterility pass covers only the units sampled2.
  • That anyone reviewed it. In the FDA's words, unapproved versions of drugs such as semaglutide and tirzepatide “do not undergo FDA's review for safety, effectiveness and quality before they are marketed,” and the FDA has warned companies that sold them falsely labeled “for research purposes”13.

Track it in the app

Sources

  1. U.S. Food and Drug Administration. Pyrogen and Endotoxins Testing: Questions and Answers (Edition 2). Guidance for industry, March 2026. fda.gov
  2. U.S. Food and Drug Administration. Sterile Drug Products Produced by Aseptic Processing: Current Good Manufacturing Practice. Guidance for industry, September 2004. fda.gov
  3. ICH. Impurities: Guideline for Residual Solvents Q3C(R9). Current Step 4 version, 24 January 2024 (copy hosted by Japan's PMDA). pmda.go.jp
  4. ICH. Guideline for Elemental Impurities Q3D(R2). Adopted 26 April 2022. database.ich.org
  5. PubChem. BPC-157, CID 9941957: molecular formula C62H98N16O22, molecular weight 1419.5, monoisotopic mass 1418.704. National Library of Medicine, read November 20, 2026. pubchem.ncbi.nlm.nih.gov
  6. Ashraf AR et al. Multifactor quality and safety analysis of semaglutide products sold by online sellers without a prescription: market surveillance, content analysis, and product purchase evaluation study. J Med Internet Res. 2024. PubMed 39509151
  7. Janvier S et al. Impurity profiling of the most frequently encountered falsified polypeptide drugs on the Belgian market. Talanta. 2018. PubMed 30029448
  8. Boullerne AI et al. Effects of peptide fraction and counter ion on the development of clinical signs in experimental autoimmune encephalomyelitis. J Neurochem. 2014. PubMed 24471474
  9. Erckes V et al. Towards a consensus for the analysis and exchange of TFA as a counterion in synthetic peptides and its influence on membrane permeation. Pharmaceuticals (Basel). 2025. PubMed 40872554
  10. D'Hondt M et al. Related impurities in peptide medicines. J Pharm Biomed Anal. 2014. PubMed 25044089
  11. Code of Federal Regulations. 21 CFR 211.84, Testing and approval or rejection of components, drug product containers, and closures. eCFR, current to November 18, 2026. ecfr.gov
  12. Code of Federal Regulations. 21 CFR 211.166, Stability testing. eCFR, current to November 18, 2026. ecfr.gov
  13. U.S. Food and Drug Administration. FDA's concerns with unapproved GLP-1 drugs used for weight loss. Content current as of October 1, 2026. fda.gov
  14. National Library of Medicine. MeSH: Pyrogens (D011749). ncbi.nlm.nih.gov
  15. PubChem. Semaglutide, CID 56843331: molecular weight 4114. National Library of Medicine, read November 20, 2026. pubchem.ncbi.nlm.nih.gov
  16. Mrozik W et al. Determination of counter-ions in synthetic peptides by ion chromatography, capillary isotachophoresis and capillary electrophoresis. J Pept Sci. 2012. PubMed 22252914

Newsletter · Weekly

The weekly peptide briefing.

New guides, the week’s peptide news, one tool. Free, one email a week, unsubscribe anytime.

We’ll email you a link to confirm. Your address is used for the briefing only. Privacy

PepVault for iPhone

Keep your protocol in PepVault

Log every dose, track every vial, and see your protocol come together.

Download on the App Store

7 days free on the yearly plan for new subscribers.

Explore the live demo